Biocartis tests four-hour breast cancer recurrence-risk assay for local labs

Biocartis has reported early results for an automated breast cancer assay designed to bring recurrence-risk testing into local laboratories. The company says its Idylla Breast21 assay returns results in under four hours and showed 93.4% agreement with an established test on high- and low-risk classifications in a 166-sample verification set.

The assay measures RNA expression for the same 21 genes as the reference test. It runs on the Idylla system using sections of formalin-fixed, paraffin-embedded tissue and returns a recurrence-risk score alongside subscores for oestrogen receptor, progesterone receptor and HER2.

The development study used 476 samples from patients with early-stage, hormone receptor-positive, HER2-negative breast cancer who already had a result from the reference assay. Biocartis used 310 samples for training and 166 for verification.

The potential benefit for local laboratories is the ability to run the assay in-house, where samples would otherwise be sent to a central reference laboratory. The reported turnaround applies to the assay itself. The study assessed how closely its results matched the existing test.

The abstract is available to read here.

Read more: Yourgene Health Insight DPYD assay receives Australian TGA approval